Commercial fridge not cooling? What to check first

Start with the simple things: the power, the temperature setting, the doors and seals, how the cabinet is loaded and whether air can reach the condenser. If the cabinet is still warm after that, or it shows an alarm, ices up or leaks water, call a refrigeration engineer, and move chilled food to a working fridge while you wait.

Published By RW Commercial Catering Engineers

What should you check first when a commercial fridge stops cooling?

These checks take a few minutes and need no tools. Work through them in order, and keep the door shut between checks so the cabinet does not lose more cold air.

CheckWhat to look forWhat you can do
PowerA blank display, no fan noise, a tripped switchCheck the plug, the switch and the fuse or circuit breaker. Williams’ troubleshooting guidance puts the power supply first when a cabinet is not working. If the breaker trips again, leave it off and call an engineer.
Temperature settingA set point that has been changed or knockedPut it back to your normal setting. Government guidance is to set fridges to 5°C or below.
Doors and sealsA door left ajar, a door alarm, a split or loose seal, frost around the doorClose the door fully and clear anything stopping it shutting. A torn or loose seal lets warm air in and needs replacing.
LoadingShelves packed tight, stock pushed against the back or the fan coverTake some stock out and leave space for air to move. Williams warns that overfilling a cabinet disrupts the air circulation inside it.
Air around the cabinetBoxes, cloths or other equipment against the grilles, a cabinet boxed in next to hot equipmentClear the grilles so air can reach the condenser. Refrigeration has to work harder as the room gets hotter.
CondenserGrey dust or greasy fluff on the condenser coil or its grilleSwitch off and unplug first. If your manual shows how, brush or vacuum the dust off the outside of the coil. A greasy coil needs a service.

What should you not do?

  • Do not chip or scrape ice off the evaporator. The evaporator is the cold coil inside the cabinet and it carries the refrigerant, so a pierced coil becomes a refrigerant leak.
  • Do not open the refrigeration circuit or add refrigerant. In Great Britain anyone who works on refrigeration containing F gas must hold an F-gas qualification, and releasing F gas into the air on purpose is against the law.
  • Do not remove panels that need tools or touch the wiring. Williams lists a failed fan motor, a faulty compressor relay and a loose electrical connection as jobs for an engineer.
  • Do not keep clearing a temperature alarm and carry on. An alarm that keeps coming back is telling you the cabinet cannot hold its temperature.

What do ice, water and alarms tell you?

Some signs point to a fault that cannot be fixed from the outside of the cabinet:

  • Ice building up on the evaporator. When the defrost fails, ice blocks the coil and cold air can no longer circulate. If your manual describes a manual defrost, you can empty the cabinet into a working fridge and follow it, but ice that returns within days means the defrost system needs an engineer.
  • Water inside or under the cabinet. This is often a blocked defrost drain.
  • The compressor running all the time while the cabinet stays warm. This points to a clogged condenser, a failed fan or a refrigerant fault.
  • An error code or temperature alarm. Codes vary by make. On Williams cabinets, for example, E1 and E2 mean a control probe failure, and the guidance for those and for a high or low temperature alarm is to call an engineer.
  • Unusual noise from the fans or the compressor.

How do you keep food safe while the fridge is down?

In England, chilled food must by law be kept at 8°C or below, and government guidance is to set fridges to 5°C or below. Chilled food can be kept above 8°C for one period of up to 4 hours. After that it must be thrown away. Food that has been above 8°C for less than 4 hours can go back into a working fridge and be kept cold until it is used.

  • Check the temperature of the food with a probe thermometer, not just the cabinet display.
  • Move the food that most needs chilling first. GOV.UK lists food with a use-by date, cooked dishes and ready-to-eat food such as prepared salads and desserts.
  • Keep the faulty cabinet’s door shut once it is empty, so the engineer can see how it behaves.
  • Write down the times, the temperatures and what you moved or threw away, in your food safety records.
An RW engineer fitting a part to a commercial upright fridge

When should you call a refrigeration engineer?

Call an engineer when the checks above have not brought the temperature down, or straight away if you see any of these:

  • The cabinet will not hold 8°C, even with the doors shut and the condenser clear.
  • An error code or temperature alarm on the display.
  • Ice on the evaporator, or water leaking from the cabinet.
  • A circuit breaker that trips again after you reset it.

When you call, have the make, model and any error code to hand, with the temperature the cabinet is showing. Wherever possible, we aim to reach you within 24 hours on working days, and our van stock means a fridge or freezer repair can often be finished on the first visit.

Commercial refrigeration repairs

How do you stop it happening again?

A condenser clogged with dust and grease cannot shed heat, so the compressor runs longer, uses more energy and the cabinet still runs warm. Williams advises cleaning condenser coils at least four times a year, with the power disconnected first.

On our planned maintenance visits, refrigeration condensers are cleaned, refrigeration pressures are checked, temperatures are verified and seals, doors and hinges are checked. Our guide How often should commercial kitchen equipment be serviced? explains the intervals.

Work inside the sealed refrigeration system, such as finding a leak or recharging refrigerant, needs an F-gas certified company. We are REFCOM certified, and our guide to F-gas rules for commercial fridges and freezers explains what the law asks of kitchen owners.

Fridge breakdown questions

Why is my commercial fridge running but not cold?

The usual causes are a condenser clogged with dust, an iced-up evaporator after a defrost failure, a failed fan, worn door seals, a faulty controller or probe, or a refrigerant leak. Check the doors, the loading and the outside of the condenser first. The rest need an engineer, and our commercial refrigeration repair page explains each fault.

Why is my walk-in cold room warm?

Check that the door closes and seals fully, that stock is not stacked against the evaporator unit and that nothing is blocking the condensing unit outside. A cold room that ices up around the door usually points to a worn door seal. We repair walk-in cold rooms and their condensing units.

Why is my commercial freezer not freezing?

The same checks apply: power, setting, doors and seals, loading and the condenser. A freezer that frosts up quickly usually has a door that is not sealing, while ice building up on the evaporator points to a defrost fault that needs an engineer.

How long can chilled food stay in a broken fridge?

Chilled food can be kept above 8°C for one period of up to 4 hours. After that it must be thrown away. Food that has been out for less than 4 hours can go into a working fridge and be kept cold until it is used, so move it as soon as you notice the fault.

How often should a commercial fridge be serviced?

Most kitchens choose a visit once a year, every six months or quarterly, depending on how hard the equipment works. Some refrigeration also needs F-gas leak checks at set intervals, which we include where they apply.

Fridge still running warm?

Call us on 01252 214067 and tell us the make and model and what the cabinet is doing, and we will arrange a visit. Our emergency call outs cover refrigeration as well as cooking equipment.

Contact us

Whether it is a general enquiry or something specific, give us a call or send us a message and we will get straight back to you.

Call us today

01252 214067

service@rwcce.co.uk

Monday to Friday, 9am to 5pm

Report a breakdown
Call 01252 214067 Contact Us